Which products are affected?
Function restriction eliminated on the 9300EP servo positioning controller as of versions V2.5 and V6.1.
Eliminated function restriction
The indication of 'current home position' under C1220/8 and C1221/8 was not updated after homing and the 'set home position' function, in absolute positioning without absolute value encoder.
Possible diagnostics?
Set home position and observe the above display codes.
Short-term measure/recommendations?
None, but there is no effect on operation of the positioning controller.
Evaluation:
Uncritical because only display values are affected.