L_TT1P_TablePositioning: Profile is not executed if lrFinalVelocity <> 0 (corrected from V3.12)

Corrected from:
L_TT1P_TechnologyModules_LM library V3.12.0.9

Response of the new version: 
When linking profiles (both profiles with final speed), the second profile will no longer be skipped, but executed correctly.
                                                                                                                                                                

What happens?
A linked positioning profile is skipped.

When does this behaviour occur?
The behaviour occurs if two linked profiles are of the same positioning type (e.g. absolute) and have a final speed.
 
Which products are affected?
L_TT1P_TablePositioningBase function block from the L_TT1P_TechnologyModules_LM library (V3.10.0.8 and higher)
 
Short-term measures:
If possible, use different positioning modes.  
Evaluation/recommendations: