L_CM1P: Bitcoding Safety Status wrong (corrected from V03.20.00)
Corrected
from: Library: (FAST Motion Modules V2) L_CM1P_ControlModules: from V03.20.00.22
Response of the new version: The bitcoding texts are correct and uniform across all TOs.
Bit 0 = STOActive Bit 1 = SS1 Active Bit 2 = SS1 Active Bit 4 = SLS 1 Active Bit 5 = SLS 2 Active Bit 6 = SLS 3 Active Bit 7 = SLS 4 Active Bit 8 = SDIpos Active Bit 9 = SDIneg Active
What
happens? Texts of the bitcodings are partly wrong:
Bit 0 = STOActive
Bit 1 = SS1 Active
Bit 2 = SS1 Active
Bit 3 = SLS 1 Active
Bit 4 = SLS 2 Active
Bit 5 = SLS 3 Active
Bit 6 = SLS 4 Active
Bit 7 = SDIpos Active
Bit 8 = SDIneg Active
When
does the behaviour occur?
Using i950 servo inverter with TA Electronic Gearbox [40], TA Sync And correction [41], TA Winder Dancer-controlled [50], TA Winder Tension-controlled [51].
The bit coding texts of parameters 0x5040:111 /0x5050:111 are displayed in the EasyStarter, for example.