i950: Synchronization function via digital input (digital IO) (from V01.14.00)

Function extension:
Application synchronization via digital input;
The application in the i950 can now also be synchronized with other devices via an external signal source and a digital input from the inverter.

Contained in the following products;
Servo inverter i950 FW:  from  V01.14.00 

Application
Synchronization of multiple inverters via an external synchronization source underusing the digital inputs of the inverters.

Related parameters:

0x2581:001 (Application synchronizationSync source), zadditionally selectable:
  • 20 : Digital input 1
  • 21 : Digital input 2
  • 22 : Digital input 3
  • 23 : Digital input 4

0x2630:10..13 (Digital input: Sync settings)
Settings for synchronization via digital input, aanalogous to the settings for synchronization via CANopen under 0x2301:10..13:Para_CAN_DI_2_a.png


Exampletopology with synchronization via digital input;

CANsync_DI.png



[Automatic Translation]
URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/202500402/1/