i950 from device size 6 (22 kW, 30 kW): Displayed energy values under parameter 0x2DA:003 not plausible (fixed from V01.14.00)
Fixed as of:
Servo inverter i950 FW: from V01.14.00
Behavior of the new version: Under parameter 0x2DA3:003, plausible energy values are now displayed under parameter 0x2DA3:003.
Description of behavior; The energy display under parameter 0x2DA3:003 shows incorrect values in certain constellations.
Under what conditions does the behavior occur?
i950 from device size BF6 (22 kW, 30 kW),
for which phase voltage measurement is active AND
the inverter characteristic curve (WRK) function is activated (0x2947: 018=[1]).
Affected products;
Servo Inverter i950 FW
Short-term measures / Evaluation / Recommendations Deactivation of theinverter characteristic curve function (0x2947=018=[0]), unless this functionality is absolutely necessary for other functions.