Question:
Can the output of FAST Application Template internal information messages be suppressed?Reply:
Yes.
In the FAST Application Template, there is the configuration module CONFIG (A12_Configuration):

If the input xLogErrorTypeInformation of the FB Config is set to FALSE, the internal
information messages can be suppressed by the FAST Application Template. On information messages,
which are triggered in the PLC program with the FB L_IE1P_SetError / L_IE1P_SetErrorSingle, this has no effect - these are still displayed.
This has no effect - they are still displayed.
The following messages are suppressed:
- MM
Coupling Disabled
- MM
Coupling Enabled
- Internal
Control Active
- Internal
Control Enabled
- Internal
Control Disabled
- Mode
Change Requested
This means that if the input xLogErrorTypeInformation is set to
FALSE, these 6 messages are not entered in the logbook and are not displayed as alarms.