L_MC2P_TappetRegister: Error message 'Fast_IO_OUT_FifoOverflow' occurs when parameterizing input eValueSource = 'mcActualValue' (fixed as of V03.30.00)

Corrected from:
Library:  L_MC2P_MotionControlCam  (FAST Motion)  as of V03.30.00
Behavior of the new version:
The switching orders of the TappetRegister are now generated correctly and the error message "Fast_IO_Out_FifoOverflow" no longer occurs.



Description of the behavior:
L_MC2P_TappetRegister: The function block generates incorrect switching orders under certain conditions.
The incorrect switching orders result in the error message "Fast_IO_OUT_FifoOverflow".  

Conditions under which the behavior occurs:

  • L_MC2P_TappetRegister and 
  • Parameterization Input eValueSource = "mcActValue" 
Affected products:
Library:  L_MC2P_MotionControlCam  (FAST Motion)

Short-term measures, Recommendations, Rating:
On FB L_MC2P_TappetRegister: set the input eValueSorce ="mcSetValue".
[Automatic Translation]
URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/202400110/1/
Formulario de contacto