c5xx, c430, i950: Technical data and communication options Profinet
Frage: What technical data and what communication options are available for the Profinet interface of the servo inverter i950. or the controllers c430 and c5xx?
Answer:
The Profinet module of the servo inverter i950 differs from the Profinet module of the controller c5xx. The Profinet module of the servo inverter i950 can NOTbe used in the controller c5xx.
The Profinet module of the controller c5xx can be used in the servo inverter i950 .
Servo inverter i950
Controller c5xx
Controller c430
Process data width
16 DWORD inputs
16 DWORD outputs
(fixed)
1 ... 250
Bytes inputs per slot
1 ... 250 bytes outputs per slot
max. 244 slots
max. 1440 bytes inputs process data
max. 1440 bytes outputs process data
Type
Communication module (0x2002:010)
I9MAFR000000
C5MAFR000000
Not
required (OnBoard)
What communications are possible via the Profinet module?