9400 with SM301 - Automatic safe torque off and safety door interlock - performance level e

Safety_SM301_STO_automatisch_Schutztürüberwachung_mit_Zuhaltung_PL_e_V1.jpg 

Function:

As soon as the motor falls below the speed limit set in C19, the SLS monitoring is activated in the SM301. If the SLS limit is fallen below, the door interlock is unlocked and the safety door can be opened. This activates STO and deactivates SLS.

If the door is closed again, the door interlock can be locked again by pressing the start button. This deactivates STO and the motor can restart. The start button must remain pressed until the speed has exceeded the limit value set in C19.

 

It is possible to open the safety door interlock with a non-safe output of the basic device and to evaluate the status by means of the safety module. In this way, the safe output of the SM301 can be used for further functions.

 
 

Safety information / disclaimer:

The safety application and parameterisation notes are examples of possible subfunctions in machines.

The T10D value according to DIN EN ISO 13849-1, Annex C.4.2 is only indicated if a B10D value is available and the operating time is less than 20 years.
 
Commissioning is prohibited until the machine has been checked in accordance with the regulations set out in the relevant EU directives / national laws.
 
The safety instructions contained in the technical documentation must be observed.
 
Using the examples does not exempt the user from careful project planning. For possible damages and consequential damages Lenze assumes no liability to the extent permitted by law.
 
Copyright 2019 Lenze Automation GmbH

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/201400328/1/