Field weakening function for synchronous motors (8400 StateLine and HighLine from V11.0, TopLine from V02.0)

Functional extension:
The possible speed range has been extended, the motor can also be operated above the rated motor speed / above the inverter limit voltage.
Please also see 'Parameterisable additional functions/field weakening for synchronous motors' in chapter 5.x.x of the software manual.
The limits of the operating range and the required monitorings are described in the stated chapter.

Which products are affected?
StateLine with firmware version V11.00
HighLine with firmware version V11.00
TopLine with firmware version V02.00

Applications:
In applications where the speed setting range of the synchronous machine is not sufficient without field weakening.

 

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/201205328/1/