9400 with SM301 - Safe direction with safety door monitoring - performance level e
Function: When the safety function is requested, the motor is stopped according to stop category 1 of EN 60204-1. In the example, the drive must traverse at safely limited speed in positive direction when the safety door is open. The negative direction is locked. When the safety door is closed, the drive may traverse in both directions without speed monitoring.
Safety information / disclaimer:
The safety application and parameterisation notes are examples of possible subfunctions in machines.
The T10D value according to DIN EN ISO 13849-1, Annex C.4.2 is only indicated if a B10D value is available and the operating time is less than 20 years. Commissioning is prohibited until the machine has been checked in accordance with the regulations set out in the relevant EU directives / national laws. The safety instructions contained in the technical documentation must be observed. Using the examples does not exempt the user from careful project planning. For possible damages and consequential damages Lenze assumes no liability to the extent permitted by law. Copyright 2019 Lenze Automation GmbH