Data width bus error code L-C13789 / L-C14789

Eliminated from:
E94AYCER communication module FW 1.30

Behaviour of the new version?
It is now possible to access the bus error code C13789 / C14789 with a data width of 32 bit without problems.



What happens?
When code C13789 / C14789 has been accessed the 32 bit value has not completely been returned correctly. Only the first 16 bit of the value have been correct.

When does the problem occur?
In case of a read request to code C13789 / C14789

Which products are affected?
E94AYCER communication module FW 0.70, 1.00 and 1.10

Possible diagnostics?
None.

Short-term measures/recommendations?
None.

Evaluation:
This display code indicates wrong values so that these may be misinterpreted by the user.

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/201001677/1/