Persistent storage of the home status HM_bHomePosAvailable

Functional description
Previously, status signal HM_bHomePosavailable at system block LS_Homing was reset after every application download and, as a result, had to be determined again following each download procedure.
In the new firmware V7.0 the status HM_bHomePosavailable is retained even after an application download and is only reset on request or if the data that determines the home position (e.g. settings of the axis measuring system) is modified.

Applications
Applications with absolute value encoders as position feedback, where the home position is set just once

Contained in which products/versions?
All 9400 HighLine axis controllers with firmware version 07.00.30.00 or higher

 

 

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/200910752/1/