AIF, mode for EtherCAT communication has been implemented, C0001 operating mode has been extended (from V5.0)

Function extension:
The process data communication of the ECS power supply module via the 2192 AIF EtherCAT module has been implemented. Up to 3 process data words each are available for transmission and reception. The AIF process data words are identical to the CAN process data words, i.e. the power supply module can be controlled via AIF just like via CAN.
Independent of the cycle time of the process data communication via the EtherCAT module, the data between power supply module and EtherCAT module are updated at a maximum rate of once per 2 ms.

Code C0001, operating mode, has been extended by the 'AIF control word Ctrl1' selection (C0001 = 2).

In which products/versions is it included?
ECS power supply module from V5.0

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/200907973/1/