Importing a parameter set when ¨error PS04¨ is indicated (from V2.2)

Which products are affected?
8400 BaseLine D (as of FW2.2)

Function description
If a BaseLine memory module is inserted from a frequency inverter with a lower firmware version (≤ 2.1) into a frequency inverter with the same performance but with a firmware version ≥ 2.2, the inverter indicates a 'PS04' error (incompatible parameter set).

By activating code C0002/12 the parameters are imported once from the memory module and then saved automatically on the memory module.
When the parameters import is complete, the inverter is completely compatible with the previously replaced device in terms of function.

Changing back to a 'lower' firmware version is not possible.

Applications
Replacement of devices equipped with on older firmware version.