Which products are affected?
9400 HighLine axis controllers from Firmware version 05.00.30.00
Functional description
The on demand mode (mode 2) has been implemented to shorten initialisation time. This mode shortens the initialisation time of the keypad because the data are not completely read from the flash anymore. Instead, a specific value is read when it is required (on demand). Mode 2 is only supported by keypads of version 02.00. The mode is set in code C00464. Keypads of version 01.00 do not support this mode and are automatically operated in mode 1 even if the user selects mode 2 in C00464.
Applications
Quick drive diagnostics or parameter adjustment via keypad.