Homing stop mode

Which products are affected?
9400 StateLine TA DS 402 FV 1.3.0
L-force Engineer

Function description
The homing stop mode object, index I-0x60Fb sub 7, is displayed in Lenze code C02641 and leads to the following changes in the list of objects:
• 0x60FB/0 Position control parameter set (new value for the number of subsequent elements: 7)
• 0x60FB/7 Homing stop mode (new object)

Applications
The homing stop mode enables the user to parameterise the intended behaviour of the controller after the home position has been detected.

Value   Description      
0          Absolute traversing to target position
1          Relative traversing around target position
2          Stop

Initial value:  0 (absolute traversing to target position)

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/200903520/1/