Mains phase failure detection (from SL:V3.0 HL:V2.0 onwards)

Function extension:
The 400 V devices are equipped with a mains phase failure detection which identifies a mains phase failure under load. If the power of the motor has been adapted to the frequency inverter, approx. 50% of the rated motor power must be exceeded in order to detect a mains phase failure. In case of a mains phase failure the error response set under code L-C00565 (default setting  = 'Warning') is executed and the error message 'Su02: Mains voltage switched off' is indicated.

Applications
Detection of a mains phase failure.

In which products/versions is it included?
8400 StateLine  SW V3.00 onwards
8400 HighLine   SW V2.00 onwards

Published with service message No. 2009/02