Adapting the deceleration ramp when the DC-bus voltage is too high (from SL:V3.0 HL:V2.0 onwards)
Function extension:
The 'Stop of the ramp function generator' setting has been added to the 'Response of the brake resistor control' (L-C00175) function. Due to the stop of the ramp function generator for the main setpoint and quick stop ramp an overvoltage disconnection can be avoided if no brake resistor is connected.
Applications
Avoiding the overvoltage disconnection with short deceleration ramps.
In which products/versions is it included?
8400 StateLine SW V3.00 onwards
8400 HighLine SW V2.00 onwards
Taxonomy:
8400 HighLine frequency inverters
,
8400 StateLine frequency inverters