Error when the CAN node is started

Which products are affected?
E82ZAFUC CANopen fieldbus function module firmware version < 1.2 in combination with the 8200 vector/motec frequency inverter series or motor starter starttec

What happens?
After being switched on the module remains in the CAN state 'Initialisation'.

When does the problem occur?
If it is tried to address to the module with one or several NMT telegrams via the CAN bus while the CAN boot-up telegram of the module is sent it may happen that the module gets stuck in the initialisation phase.

Possible diagnostics?
If the initialisation state (selection 0) is permanently indicated under code C1530 and the communication LED is also off permanently after the module has been switched on.

Short-term measure/recommendation
None.

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/200607469/1/
Formulario de contacto