Extension of the TP interfaces in CDATA and CCTRL2 function

Which products are affected?
9300 servo cam profiler V7.1

Applications
Cam drives and other servo applications which contain the register generation function and require a mark synchronisation in the register.

Description
The  CDATA and CCTRL2 function blocks have been extended by the CDATA-TP-EDGE-SELECT and CCTRL2-TP-EDGE-SELECT inputs.
The TP sensors at DIGIN4 and DIGIN5 can be evaluated correspondingly by activating the inputs as follows:
 FALSE  = (negative edge) or
 TRUE  = (positive edge)

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/200604273/1/
Formulario de contacto