Overvoltage and low voltage is insufficiently indicated by the Fail message

Which products are affected?
Keypad XT (version 3A21) in combination with 8200vector/motec and 9300

What happens?
Instead of a selective overvoltage message and low voltage message only the 'Fail' message is indicated on the display.

When does the problem occur?
In case of overvoltage/low voltage of the DC bus

Possible diagnostics?
The diagnostics via keypad is only possible in case of overvoltage/low voltage in the DC bus.

Short-term measures/recommendations?
Use of a keypad with firmware version 2.2 or higher

Evaluation:
The error cannot clearly be assigned with regard to overvoltage and low voltage by means of the keypad.

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/200504798/1/
Formulario de contacto