Menu-assisted code access of keypad XT in connection with the fieldbus function module Profibus I/O and selection

Which products are affected?
Keypad XT EMZ9371IBC in software status 2.1 in connection with the fieldbus function module Profibus I/O E82ZAFPC201

What happens?
The assignment of the PROFIDrive control- and status word in codes C1510 and C1511 cannot be selected by means of the main menu 'FIF fieldbus'  and main menu 'All'.

When does the problem occur?
When the keypad XT version 2.1 is used with the fieldbus function modules Profibus I/O E82ZAFPC201 and application of the PROFIDrive Profiles.

Possible diagnostics?
When the fieldbus function modules Profibus I/O E82ZAFPC201 are used, the selection PROFIDrive control and status word are not displayed.

Short-term measures / recommendations?
The possible selections PROFIDrive control and status word of the module can be made by means of the keypad E82ZBC or by means of the Lenze parameter setting software GDC Easy or GDC.

Evaluation:
No.