ErPxx error messages in combination with the keypad

Question:

Which meaning have ErPxx error messages which are not described in more detail in the product documentation of the 8200motec/vector?

Answer:

ErP 00:  Basic device does not accept the component part (e.g. 8212 from the software ID number 82S8212V_14000) of the software ID number in the parameter set of the keypad.
Reason:  The software version of the basic device is lower than the one of the data set inside the keypad (e.g. the keypad is parameterised with a basic device software 2.x but the basic device has a software version SW 1.x).

ErP 01:  Transfer of basic device parameter set 1 is aborted
Reason:  The data of the basic device parameter set 1 are not correct (e.g. faulty data storage in the keypad; data in the keypad were created on another controller).

ErP 02:  Transfer of basic device parameter set 2 is aborted
Reason:  The data of the basic device parameter set 2 are not correct (e.g. faulty data storage in the keypad; data in the keypad were created on another controller).

ErP 03:  Transfer of basic device parameter set 3 is aborted
Reason:  The data of the basic device parameter set 3 are not correct (e.g. faulty data storage in the keypad; data in the keypad were created on another controller).

ErP 04:  Transfer of basic device parameter set 4 is aborted
Reason:  The data of the basic device parameter set 4 are not correct (e.g. faulty data storage in the keypad; data in the keypad were created on another controller).

ErP 07:  Basic device does not accept the length of the basic device parameter set.
Reason:  The parameter set in the keypad has a wrong length and is therefore not accepted by the basic device.

ErP 08:  Checksum error in the parameter set storage of the basic device paramater set of the keypad.
Reason:  Faulty data storage in the keypad.

ErP 09:  AIF communication error detected in the keypad while transferring the parameter set.
Reason:  Contact problem at the AIF interface.

ErP 10:  Function module does not accept the component part (e.g. AFA0 from the software ID number 82SAFA0B_14000) of the software ID number in the parameter set of the keypad.
Reason:  The software version of the function module is lower than the one of the data set inside the keypad (e.g. the keypad is parameterised with a function module software 2.x but the function module has a software version SW 1.x).

ErP 11:  Transfer of parameter set 1 of the function module is aborted
Reason:  The data of the parameter set 1 of the function module are not correct (e.g. faulty data storage in the keypad; data in the keypad were created on another device).

ErP 12:  Transfer of parameter set 2 of the function module is aborted
Reason:  The data of the parameter set 2 of the function module are not correct (e.g. faulty data storage in the keypad; data in the keypad were created on another device).

ErP 13:  Transfer of parameter set 3 of the function module is aborted
Reason:  The data of the parameter set 3 of the function module are not correct (e.g. faulty data storage in the keypad; data in the keypad were created on another device).

ErP 14:  Transfer of parameter set 4 of the function module is aborted
Reason:  The data of the parameter set 4 of the function module are not correct (e.g. faulty data storage in the keypad; data in the keypad were created on another device).

ErP 17:  Function module does not accept the parameter set length of the function module.
Reason:  The parameter set in the keypad has a wrong length and is therefore not accepted by the function module.

ErP 18:  Checksum error in the parameter set storage of the function module parameter set of the keypad.
Reason:  Faulty data storage in the keypad.

ErP 19:  AIF communication error in the keypad detected while transferring parameter sets.
Reason:  Contact problems at the AIF interface.