Control configuration extended by STATEBUS_IO

Which products are affected?
ESP-SP-POS1 ― Positioner Software Package V3.3
Positioner Template

Function description
The STATEBUS_IO system block is integrated into the control configuration according to the default setting. The control configuration is uniform for the templates Pos, Cam, Winder.

Applications
This system block can set the state bus to LOW level in order to control/lead all stations connected to the state bus (Lenze drive controllers/PLC only) into/to a pre-selected status (e. g. TRIP, QSP or controller inhibit).