Additional display codes

Which products are affected?
ESP-SP-POS1 ― Positioner Software Package V3.3
Positioner Template

Function description
  • Display of the current target position or distance in units under C3057
  • Display of the minimum permissible profile velocity under C3063
  • Display of the template status under C3065 (e.g. stand by, positioning)
  • Display of the profile generator status under C3066 (e.g. acceleration phase is active, constant velocity phase is active). The profile generator status is indicated with an offset of +16000, e.g. the status message 'constant velocity phase is active' (g_nPosProfilerState=11) under code C3066 is indicated as 160011 with the plain text ConstantSpeed.

Applications
Drive diagnostics via codes, e.g. keypad.

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/200403426/1/