Spezification temperatur switch on the brake unit

Question:

At what temperatur does the temperatursensors in the Brake unit EMB9351 open?

Answer:

The klixon-temperatursensors on terminal T1 and T2 open at a max. temperatur of the heatsinkt of 130 °C ±5 °C.

Additional spezifications:
  • characteristic: break-contact
  • threshold voltage 250 VAC
  • max. threshold current 25 AAC
  • max. continuous current 6.3 AAC, 10 ADC