i750ES/AS: Brake status is displayed incorrectly in EasyStarter (fixed from V01.03.08)
Removed from:
i750 Extended Safety (ES): ab V01.03.08 i750 Advanced Safety (AS): ab V01.03.08
Behavior of the new version:
The brake status is always displayed correctly
For the conditions described below
The safety function SBC is deactivated
and the safe fieldbus communication FSoE is not yet established => state "INIT",
and the brake is to be opened by "overriding the brake control 0x2820:011 "Open brake [1]".
The status bit 19 in the object "Safety-State 0x2870:002" is now set. The brake is engaged in this state and the status displays signal the correct brake status: 1. status shows "Brake detection - 0x2820:004 = Brake detection not started [0]" 2. Status displays "Brake status - 0x2820:015 = Brake closed [0]"
Description of behavior:
The brake status display in Easy Starter is incorrect. It is displayed that the brake is open, although the brake is closed.
Under what conditionsdoes the behavior occur?
The safety function SBC is deactivated
and the safe fieldbus communication FSoE is not yet established => state "INIT",
and the brake is to be opened by "overriding the brake control 0x2820:011 "Open brake [1]".
Effect: The status bit 19 in the object "Safety-State 0x2870:002" is not set. The brake is engaged in this state and the status displays signal an incorrect brake status: 1. status displays "Brake detection - 0x2820:004 = Brake detected [3]" 2. Status displays "Brake status - 0x2820:015 = Brake released [1]"