Function extension:The value range is limited in FW version V1.0 in the way that a maximum transmission ratio of i=500 can be realized.
As of firmware version V1.1, the maximum transmission ratio is i= 655.35.
Code number 15501 Position encoder gear factor Factory setting is 100%.
Setting of the gear factor between motor and position encoder,
e.g. 100 % => i = 1.00
2543 % => i = 25.43
65535 % => i = 655.35
Contained in which products?
Safety module SM302 FW Version 1.10
Usage:
Safety functions with two-encoder concept and higher gear ratio