Due to different versions of the control card, not every firmware version on any 9400 device.
The control card actually installed in the servo inverter must be identified via parameter C210/1.
The following overview shows the dependencies between the controller card version and the firmware version.
| Version of Firmware 9400 HighLine |
9400 Hardware version of the control board |
Identification |
| from V15.50.07 | Revision 3 und Revision 3 AA und Revision 5 BC | C210/1 = 3x oder C210/1 = AA oder C210/1 = BC |
from V15.02.05
| Revision 3 and 3 AA | C210/1 = 3x or C210/1 = AA
|
from V15.00.09
| Revision 3 only | C210/1 =
3x |
| from V14.08.00 to V14.13.00 | Revision 2 and Revision 3 | C210/1 =
2x or
3x |
| from V10.00.15 to V13.01.06 | Revision 2 only | C210/1 =
2x |
|
Version of Firmware 9400 Servo PLC |
9400 Hardware version of the control board |
Identification |
| from V09.50.07 | Revision 3 und Revision 3 AA und Revision 5 BC | C210/1 = 3x oder C210/1 = AA oder C210/1 = BC
|
from V09.02.05
| Revision 3 and 3 AA
| C210/1 = 3x or C210/1 = AA
|
| from V09.00.09 | Revision 3 only | C210/1 =
3x |
| from V08.05.00 to V08.13.00 | Revision 2 and Revision 3 | C210/1 =
2x or3x |
| from V01.70.06 to V07.01.06 | Revision 2 only | C210/1 =
2x |
Automatic Translation