Which products are affected?
HighLine with firmware version V11.00
TopLine with firmware version V02.00
Functional description
A lot of functions/function blocks have been added:
• The implementation of 4 position switch points (L_SwitchPoint_1) enables the control of signals depending on the actual position.
• Linear profile generator (L_PosCtrlLin) for simple positioning applications with trimming/offset adjustment.
• The block (L_GearComp) can be used to compensate for elasticities in the drive train.
• The 'LS_RetainData' system block serves to save process values of the inverter which can be set again in the inverter after a mains connection/disconnection process.
• Signal switch-over of 32-bit signed signals with the L_SignalSwitch32_x.
• Conversion of a universal 16-bit value with numerator and denominator with the remainder considered using the L_ConvX_x function block.
• Conversion of an angle signal with numerator and denominator with the remainder considered using the L_ConvPP_x function block.
• Conversion of an angle signal into an analog signal and back again using the L_ConvPA_x and L_ConvAP_x function blocks.
• Increase in the number of available function blocks for L_Curve_x.
• For the sake of readability, the signal names of LS_ParFree function blocks were renamed in the parameter number the respective signal was defined from.
Applications
Extension of the general solution space of applications and simplification of applications.