C3012 Offset reference measuring system - Extended value range for soft motion operation (from V4.0)

Function extension:
Up to now, code C3012 'Offset reference measuring system' covers a value range of +/- 2,140,000,000 inc.
The limit for a 32 bit variable has now been extended to the max. possible value range of +/- 2,147,483,647 inc.

If values outside the value range of code C3012 are written the soft motion indicates 'WSP Sending Error' because the value has not been accepted by the drive controller.
This problem does not occur anymore if the value has been extended to the maximally possible values.

Included in which products/versions?
ECS Motion from V4.0

Applications:
Operation of an ECS Motion drive controller with a Lenze IPC or Lenze Controller 3200 with equipped with soft motion and use of code C3012 'Offset reference measuring system'. Especially in case of module axis it may happen that the complete offset value range under C3012 is required.

Search terms: Error 131, modulo axis

CR ID: LDS00028153
Failure Report ID: 9456
Published with Service Message No. 2012/xx

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/201112882/1/