CANopen - ¨HeartBeat Consumer¨ protocol function available (from SL:V3.0 HL:V2.0 onwards)

Function extension:
The 'HeartBeat Consumer' protocol function enables an 8400 StateLine frequency inverter to monitor up to 7 and an 8400 HighLine frequency inverter to monitor up to 15 further devices via CAN bus by means of the 'HeartBeat' telegram. If a 'HeartBeat' telegram of one or several nodes is missing the monitoring frequency inverter responds with the error response selected (L-C00592/5).

Applications
Monitoring the CAN communication between several frequency inverters or one control

In which products/versions is it included?
8400 StateLine  SW V3.00 onwards
8400 HighLine   SW V2.00 onwards

Published with service message No. 2009/02

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/200902737/1/