Charging current control, C0022 maximum charging current, setting range extended up to 32A (V4.0 onwards)
Function extension:
In the case of the most powerful ECS power supply module, ECSxE040, the setting range of code C0022 has been extended as follows for the maximum charging current of the DC circuit after the power supply has been enabled:
New: 2.0...32.0A (previously: 2.0...25.0A).
Note relating to the English pdb file:
Unfortunately, the extended setting range for C0022 is not yet available in the accompanying English version of the device description file (*.pdb), as is installed in GDC V4.11 and GU14.
The corrected English pdb file will be made available in the next device data update (GU15), expected in mid 2009. Should it be urgently required before this date, please consult our head office
In which products/versions is it included?
ECS power supply module V4.0 onwards