Identifier setting is not saved with mains failure protection

Which products are affected?
EPM-T110 (CAN Gateway V1.2)

What happens?
The identifier settings under indices I1400 hex and I1800 hex are not saved with mains failure protection by means of index I1010 hex .

When does the problem occur?
The response described above occurs if the CAN gateway is in the CANopen (I2361 hex = 1) mode.

The Lenze System bus mode is not affected by this function restriction.

Possible diagnostics?
None.

Short-term measures/recommendations?
Whenever the CAN gateway is switched on, use a higher-level control to parameterise the indices of the identifier settings.

Evaluation:
The process data object identifiers are not saved with mains failure protection when the CAN gateway is in the CANopen mode. Usually the parameters of the I/O system are set in the CANopen by a higher-level control immediately after switching-on the machine.
According to the Lenze default setting the Lenze System bus mode, which is not affected by this function restriction, is selected.

 

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/200708828/1/