Digital output signal selection ¨Status Motor 1¨ and ¨Status Motor 2¨

Which products are affected?
Starttec, all designs for multi-motor operation or change of the direction of rotation, from SW version 2.0 on

Function description
The digital output signal selections 'Status Motor 1' and 'Status Motor 2' (C0415/C0417/C0418) have been extended as follows:
  • Status Motor 1 / CW rotation: (C0415/x = 3, C0417/x = 3, C0418/x = 3): Motor 1 operating / CW rotation activated = HIGH
  • Motor 1 stopped / CW rotation inactive = LOW
  • Status Motor 2 / CCW rotation (C0415/x = 4, C0417/x = 4, C0418/x = 4): Motor 2 operating / CCW rotation activated = HIGH
  • Motor 2 stopped / CCW rotation inactive = LOW

Applications:
Output of the motor/direction of rotation status signals via the digital outputs or the starttec status messages.

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/200500295/1/