Time required for debouncing TouchProbe signals

Which products are affected?
ESP-SP-POS1 ― Positioner Software Package V3.3

Function description
In case of bouncing TouchProbe initiators it may be possible that the edges are evaluated incorrectly. The evaluation of further edges can be deactivated via the programmable debouncing time for the TouchProbe input after an initially recognised edge. The time required for the deactivation is entered in milliseconds [ms] under C3036.
The deactivation is cancelled if the time under C3036 has expired or if a new profile has been started.

Applications
Safe edge evaluation of bouncing TouchProbe sources.

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/200403425/1/