Difference description 2175IB SW V0.6 to V0.7
1. Product identification
- article number new (V0.7): 403940 or 416657
- construction labelling new: 2175IB.VB.07 or 2175IB.VC.07
- ordering designation: EMF2175IB
- article number old (V0.6): 403940
2. Function improvements
Application
When using the CanOpen communication profile the monitoring time can be set by under code L-C2357.
Description
During operation with the 9300 IEC1131 drive controllers modifications under code L-C2357 subcodes 1 to 3 (monitoring times for the single CAN channels) have not been adapted. As a result, the monitoring time has been set to 3000 ms although the code display has been changed.
Elimination
The behaviour described above has been eliminated in software version V0.7.
Short-term measure in the previous version
None
Possible diagnostics