CONVPHA2 and CONVPHA3 for converting angle signals

Application:
  • Servo cam 9300
  • Convert angle signal => analogue signal

The remainder is not processed when converting from an angle signal to an analogue signal as opposed to the function blocks of the same name with servo positioning controller 9300. The function blocks are therefore only suitable for analogue further processing (e.g. analogue output of length signals, following errors, ...). Reverse conversion to an angle is no longer true to position. Angle difference signals (master frequency processing) cannot be implemented.

If an angle has to be transferred via analogue channels of the CAN bus, the converters CONVPHAA1 and CONVPHAA2 are available.