In a PLC application where the current compiler version V3.5.16.20 is set, complete structures or a complete array can be accessed via OPC UA without the OPC UA server stopping.
What happens?
Communication with the OPC UA Server stops. Communication with PLC Designer is still possible. To reestablish OPC UA communication the controller must be restarted.
When does the behaviour occur?
In the PLC application the compiler V3.5.14.40 is set. A complete structure or array is accessed via OPC UA. It is possible to access a single structural element or an individual array element.