Communication error when adjusting the pole position using the EQI1329 EnDat encoder (remedied from V5.0)
Remedied from?
9400 HighLine SW V5.0 not eliminated at 9400 StateLine up to Version 4.0
Eliminated function restriction
When adjusting the pole position (C02=51) using the EQI1329 EnDat encoder the C03=339B23H communication error occurred. The error occurred after the adjustment of the pole position was completed and the position was transferred between the encoder and the standard device. The revision enables trouble-free adjustment of the pole position using the EQI 1329 EnDat encoder now.
Taxonomy:
9400 HighLine servo inverters
,
9400 StateLine servo inverters
AKB-ID:
200904094
Last update:
2023/09/09
Category:
Informations sur la version
Lenze reserves the right to change information on this page at any time. Any liability for the accuracy of the information is excluded.