Charging current control, display code C0023 for the peak current of the thyristor (V4.0 onwards)
Function extension:
The display code C0023 functions as a drag indicator measuring instrument. The peak thyristor current is observed, saved and displayed via all previous loading processes of the DC bus. The respective display value is automatically saved to the device when the mains is switched off (operating system record 2) and is thus still available when switched back on.
The C0023 peak current display is reset to code C0022 (charging current setting) with write access.
In which products/versions is it included?
ECS power supply module V4.0 onwards
Taxonomy:
ECSxA application
,
ECSxE power supply module
,
ECSxK capacitor module
,
ECSxM motion
,
ECSxP position and shaft
,
ECSxS speed and torque
,
ECS servo inverters
AKB-ID:
200901419
Last update:
2023/09/09
Category:
Informations sur la version