Manual operation of the ECS without higher-level control
Which products are affected?
ECSxM as of V1.2
Function description
The selection of the control interfaces under C4010 has been extended. The control option via application control word is now available, too (C4010 = 3). All control bits can be set via the code in the application control word. Therefore, a CAN communication is no longer required for control purposes.
As a result, the drive can be traversed without an external control in order to check e.g. the basic drive functions.
Taxonomy:
ECSxA application
,
ECSxE power supply module
,
ECSxK capacitor module
,
ECSxM motion
,
ECSxP position and shaft
,
ECSxS speed and torque
,
ECS servo inverters