Eliminated function restriction:
In contrast to the positive input signals at the DFRFG1-IN function block the output profile generated has not been created correctly in case of negative input signals. The added input signal should generate a corresponding output profile as soon as a LOW level is assigned to the DFRFG1-QSP signal. This was not the case with negative input signals since in the DFRFG1 function block a wrong interpretation and handling of the internal states existed.
The comparison request between the input signals at DFRFG1-IN has been changed. Now, the comparison is made with 'DFRFG1-IN > 0' and no longer with 'DFRFG1-IN ≥ 0'.
Taxonomy:
9300 vector EVF93xx-EH hoist frequency inverters
,
9300 vector EVF93xx-EV frequency inverters
,
9300 vector frequency inverters
AKB-ID:
200603284