Motor jerks when being operated in inching mode (elimination)
Which products are affected?
9321…9323 vector 0.37…1.5 kW SW V7.1
Eliminated function restriction?
If the controller is inhibited for a short period of time (shorter than the demagnetisation time of the machine) the decay time of the flow will now be considered. Thus, an unintended rotary motion after re-enabling the controller will be avoided. The time required for demagnetising the machine is calculated inside the controller by means of the motor parameters.