QSP is not displayed when controlling the drive via CAN-IN1
Which products are affected?
9300 vector 0.37…90 kW SW ≤ V6.3
What happens?
When activating the quick stop function (QSP) via CAN-CTRL.B3, QSP is executed by the controller. However, this is not indicated by the drive status (C0183).
When does the problem occur?
If the quick stop function (QSP) is activated via CAN-CTRL.B3.
Possible diagnostics?
Check whether the CAN-CTRL.B3 output is used in the drive control.
Short-term measures/recommendations?
None.
Evaluation:
The error occurs immediately during commissioning.
Taxonomy:
9300 vector EVF93xx-EH hoist frequency inverters
,
9300 vector EVF93xx-EV frequency inverters
,
9300 vector frequency inverters
AKB-ID:
200504943
Last update:
2023/09/08