Optimisation of the control of the UG relay when aborting the charging process (V2.3 onwards)
Which products are affected?
Supply module ECSxE series, operating software V2.3
Function description
With abortion of the charging process it is ensured that the charging thyristor is extinguished before the –UG relay is opened. As a result it is avoided that an arc occurs and the relay wear is reduced.
Applications
Interruption of the charging process after mains connection of the ECS servo system.