The maximum torque indicated under code C0057 is calculated from the nameplate data entered by the user and the set maximum current (C0022).
In the vector control mode (C0006 = 1) it is considered that the motor current is divided into a torque-generating part and a field-generating part.
As a result, the actual torque indicated in MCTRL-MACT corresponds more exactly to the torque that is actually output at the motor shaft.
Note: The signals MCTRL-MACT and MCTRL-MSET2 are indicated in percent under C0057 i.e. the maximum torque indicated under C0057 corresponds to 100 %.
Applications
If the MCTRL-MACT is evaluated externally, e.g. in a super-imposed control.
Taxonomy:
9300 vector EVF93xx-EH hoist frequency inverters
,
9300 vector EVF93xx-EV frequency inverters
,
9300 vector frequency inverters
AKB-ID:
200402065
Last update:
2023/09/08
Category:
Informations sur la version
Lenze reserves the right to change information on this page at any time. Any liability for the accuracy of the information is excluded.