L_MC4P: L_TC2P_CoordinatedMotionState: Kinematics stops with error message "master axis not ready" (fixed from V03.32.00)
Removed from: Library: L_MC4P_RoboticHandling (FAST Motion) as of V03.32.00 L_TC2P_TechModulesCoordinatedMotionBasic as of V03.32.00
Behavior of the new version:
If the master axis switches to the error state, the error message is no longer forwarded to the coupled AxesGroup and the AxesGroup continues to move synchronously.
Description of the behavior: The AxesGroup switches to the error state with error message "master axis not ready".
Conditions under which the behavior occurs:
p style="font-weight:bold;">
Tracking functionality from the L_TC2P library is used and
the AxesGroup moves synchronously with a ConveyorBelt axis and
the ConveyorBelt-axis switches to the error state.
Taxonomy:
Lib L_MC4P_RoboticHandling
,
Lib L_TC2P_TechModulesCoordinatedMotionBasic
AKB-ID:
202400111
Last update:
2025/08/07