Control word Ctrl1, display under C4270/x incorrect (remedied from V2.0 onwards)
Remedied from:
ECS Posi&Shaft V2.0 onwards
Behaviour of the new version?
Codes C4270/x now correctly display the signal status of the control bits.
What happens?
The control word Ctrl1 is not correctly displayed under the display codes C4270/x for the respective control interface. However, the actual function of the individual control bits is provided.
When does the problem occur?
Continuously, if activated by the corresponding setting of the control interface under C4010.
Which products/versions are affected?
ECS Posi&Shaft <= V1.3
Possible diagnostics?
Display codes C4270/2 and /3 differ from codes C0136/2 and /3.
Short-term measures/recommendations?
None.
Evaluation:
Only the display codes are affected; the actual control bit function of control word Ctrl1 is fine.
Taxonomy:
ECSxA application
,
ECSxE power supply module
,
ECSxK capacitor module
,
ECSxM motion
,
ECSxP position and shaft
,
ECSxS speed and torque
,
ECS servo inverters
AKB-ID:
200900981
Last update:
2023/09/09
Category:
Informations sur la version